(1)Material: carbon steel/cast iron (2) Power: 1.1-18.5KW (w) (3) Flow rate: 0-45 (L/S) (4) Efficiency: 79 (%) (5) Model: XBD/LG/QW/WQ/ZW(L)/ZW(W) (6) Pressure : 0-2.5 (MPa) (7) Speed :2900(r/min)) (8) Pump shaft position: side vertical type (9) Impeller structure: closed (10) Number of impellers: 3-10 (11) Impeller suction mode: single suction type (12) Water supply flow: fire pump: 40L/s; pressure regulating pump: 1.5 L/S (13) Water supply pressure: fire pump: 0~1.6kW; pres
Device composition
HRB-503 Fire-fighting water supply system piping installation trainer mainly consists of small imported pneumatic tank/domestic diaphragm type pneumatic tank, fire hydrant water pumping unit, automatic sprinkler pumping unit, pipe valve accessories and control cabinets and other configurations, of which high-power fire-fighting water supply equipment by the fire hydrant water pumping unit Constitute a set of fire hydrant sprinkler system
1, fire hydrant equipment: by the water gun, water belt, fire hydrant composition.
(1) single-exit hydrant, double-exit hydrant each 2, DN65. polyamide water belt: 65mm, length 13m, pressure capacity of 0.75MPa, the water gun: 16mm. while with standard fire reel and 20m fire hose.
(2) water supply pipe network, from the introduction of the fire main pipe, fire riser and related valves and valves. The water supply pipe network and related valve accessories are all made of materials required by the water supply specification of the fire fighting system to meet the pressure-bearing capacity of the fire fighting water supply system;
(3) Water supply pipe: 100mm diameter galvanised steel pipe; valves: check valve, gate valve, safety valve. All valves meet the requirements of the fire system specification standards and have proof of inspection;
(4) Roof fire hydrant for fire hydrant water supply system inspection and trial use. Single outlet hydrant: DN65; water pump connector, fire fighting pool, fire fighting tank and other components.
2、Pump coupler: above ground type, implementation standards:
(1) Product standards "fire pump coupler" GB 3446
(2) engineering standards "building design fire code" GB 50016
(3) "Building water supply and drainage and heating engineering construction quality acceptance norms" GB50242;
Functional practical training:
1. Wet alarm valve installation training
2. Installation training of high water pumps
3. Fire pump installation training
4. Installation of fire retarder training
5. Fire pipeline connection operation training
6.Control system wiring training
7.System connection and wiring training
8.Installation training of fire fighting equipment
9.Networking with the fire centre equipment debugging programming training
10.Networking with the sprinkler sub-system programming training
20. Pipe processing and connection: galvanised pipe, PPR, UPVC pipe cutting, sleeving, welding, connection.
21. Installation of fittings and devices: complete the installation of piping fittings in the fire water system;
22. complete the installation of water pumps, pressure transmitters, water meters, float level meter, signal butterfly valves, wet alarm valve group, water flow indicator, closed nozzle, end of the water test device, nozzle, pump devices .
Contact: Gustavo Zhang
Phone: +86 18966252578
Tel: +86-577-67318236
Email: Gustavo@hengrytech.com
Add: Yongjia county, wenzhou city, zhejiang province ou the five-star industrial zone north street